P0EB1 A/C Compressor Motor Phase U Current Sensor Circuit
Electric A/C compressors run a three-phase permanent-magnet motor whose inverter measures the phase currents in order to commutate it and limit torque. P0EB1 is the general circuit fault of the phase U current sensor: the controller gets no usable signal and gives no finer verdict on it. P0EB1 is not described in any public maker document. GM's 2011 Volt checked the same sensors under the older codes P0D7A to P0D7F, testing at standstill with zero speed request; any reading of 68 A or more in either direction (30 of 60 samples, 50 ms) counted as a sensor fault, Type B, and only a 12 V reset allowed a new pass. The sensor belongs to the inverter, so the usual repair is the compressor assembly. U-phase details: P0EB2 to P0EB4.
Likely causes
Symptoms
- Compressor does not run, cabin stays warm
- Climate system warning