P0EB2 A/C Compressor Motor Phase U Current Sensor Circuit High
P0EB2 is set when the phase U current sensor of the electric A/C compressor sends a signal above its valid window. Current sensors in such inverters often output a voltage centred on zero current, so a stuck-high output reads like a large current in one direction even with the motor at rest. No manufacturer documents P0EB2 publicly. GM's 2011 Volt ran a standstill test that catches exactly this: plus 68 A or more on phase U with no speed request set the older code P0D7A, Type B. A short to the sensor supply, a damaged Hall element or a fault on the inverter board are typical. The compressor controller stops the motor to protect the power stage. P0EB3 covers the low side; P0EB5 and P0EB8 report the same fault on phases V and W.
Likely causes
Symptoms
- Compressor will not start or stops at once
- No cooling during hot weather
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, law.cornell.edu.