P27C7 Pressure Control Solenoid P Control Circuit Low
P27C7 points to a control circuit of solenoid P that is too low, effectively a short to ground on the switched side. GM's 23OBDG07 Corvette dual-clutch table checks synchronizer actuation valve 3 with its low-side switch on and expects the sense resistor voltage to be pulled down only so far; a reading under about 1.7 V (±0.5 V) for 150 ms is reported by the driver chip as a ground short, Type A, provided the engine is not cranking and battery voltage lies between 8.75 and 18 V. With that line grounded, valve 3 may stay energized regardless of command. Ford lists the same failure as a shorted switch on SPV3 of the TR9070. Inspect harness routing near the case and the connector for moisture.
Likely causes
Symptoms
- MIL on
- Unwanted application of rods 3/4, gears blocked
- Limp mode
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, gsi.ext.gm.com, gsi.ext.gm.com, fordservicecontent.com.