P27C8 Pressure Control Solenoid P Control Circuit High
P27C8 signals too high a level in the control circuit of solenoid P. GM's Corvette DCT tables 23OBDG07 and 24OBDG07 store it for synchronizer actuation valve 3 in three situations, all Type A. First, with the low-side switch on, the sense voltage stays above a supply-dependent limit of 0.7, 0.9 or 1.1 V (below 11.5 V, 12-15 V, above 15.5 V battery). Second, the current estimated from duty cycle and supply deviates from its target by more than 70 % (60 ms) or by more than 400 mA (300 ms). Third, a shutdown routine switches each output separately, detects valve 3 shorted to a neighbour and sets the code at the next start. Ford calls it shorted load on SPV3 of the TR9070.
Likely causes
Symptoms
- MIL on, possibly at the start after a previous drive
- Gears of rods 3/4 unavailable
- Limp mode
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes