P2BE9 Hybrid/EV Battery Precharge Contactor Control Circuit B Range/Performance
P2BE9 says control circuit B of the precharge function is connected but behaves implausibly: the coil current, the feedback voltage or the effect of switching does not match the command. No manufacturer documents P2BE9 publicly. A Ford patent shows why the result of precharge matters for a second path: if the main contactor stays welded, the controller switches precharge to the resistor bridging the return-side contactor, and it must then confirm that the bus voltage actually rises. GM judges the outcome of precharge separately (P0C78): in its 2019 tables the bus must reach 95 to 105 % of pack voltage within 0.7 s, Type A. CARB demands functional checks of hybrid outputs. Open, low and high are P2BE8, P2BEA and P2BEB.
Likely causes
Symptoms
- Vehicle sometimes does not become ready
- MIL and hybrid or EV warning on
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, patents.google.com, gsi.ext.gm.com.