P2BEB Hybrid/EV Battery Precharge Contactor Control Circuit B High
P2BEB reports too much voltage on control circuit B of the precharge function while it should be off, usually a short to 12 V or a driver that does not switch off. The risk is a second precharge path closing on its own; the resistor can overheat if it stays in circuit. No manufacturer documents P2BEB publicly. For contactor A, GM's 2016 table (P0AE7) fails the off-state output between 5.27 and 19.7 V, 40 of 50 samples at 12.5 ms, Type B, two trips; in 2019 GM folds this case into P0AE4, set when the off-state output exceeds battery voltage minus 0.4 V. A coil stuck energised may later show up as a contactor that stays closed. CARB requires circuit monitoring of hybrid outputs. Low and open are P2BEA and P2BE8.
Likely causes
Symptoms
- MIL and hybrid or EV warning on
- High-voltage system blocked as a precaution
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, gsi.ext.gm.com, gsi.ext.gm.com.