Powertrain, generic · Hybrid propulsion

P0BEC Drive Motor A Phase V Current Sensor Circuit High

Check engine lightOn
EmissionsRelevant
Drive cycleNot required
Limp modePossible

P0BEC is set when the phase V current sensor of the motor A inverter reports a value above its valid range. In GM's tables the limit is above 700 A for 0.05 of 0.1 s (2016) or 0.1 of 0.15 s (2019), Type A; above 800 A, Type A, on the 2011 Volt with PWM output disabled; and above 700 A, Type B, two trips, on the 2012 two-mode trucks. Because the check runs while the power stage is not switching or the value is far beyond any real current, it isolates a sensor or supply fault rather than an actual overcurrent. It pairs with P0BEB for the low side and P0BEA for offset. Expect reduced drive from motor A and further inverter codes in the memory.

Likely causes

Failed phase V current sensor inside the inverter
Sensor signal shorted to the sensor supply voltage or open reference ground
Poor contact at an internal or external inverter connector

Symptoms

  • Malfunction indicator lamp and hybrid warning
  • Reduced power from drive motor A

Repair estimate

DifficultyShop_onlyWorkshop job
Parts and labour€150–4,000
Time1–6 h

Typical range across vehicles; the real cost depends on what the testing finds.

Parts involved

drive motor a phase v current sensorwiring harnesshybrid control module

Related codes

References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.